Engines - EICAS (GE)

Introduction

The Engine Indication and Crew Alerting System (EICAS) consolidates engine and selected subsystem indications as well as crew alerting functions. The system includes two colour cathode ray tubes (CRTs), two computers and a control panel.

A Computer Selector determines which computer controls EICAS CRTs. When the selector is in the AUTO position the Left computer is used. If the Left computer fails, control switches to the right computer. When the L position is selected only the left computer can control the CRTs. When the selector is in the R position only the right computer can control the CRTs. This can be used to correct display faults not automatically detected by the system.

The brightness controls are used to adjust the brightness level of the CRTs. The inner knob controls the upper display brightness and the outer knob controls the lower display brightness. Turning either knob adjusts the brightness level of both displays by the same amount. To adjust the brightness level of a single display, one knob must be held stationary while the other knob is adjusted.

Engine Indications

Primary and secondary engine indications are provided. Engine indications are displayed on the EICAS display. In addition, annunciator lights and a liquid crystal Standby Engine Indicator are provided to monitor engine operation.

Primary Engine Indications
Eicas Upper

N1 and EGT are the primary engine indications [and] are displayed on the upper EICAS display.

Warning, caution and advisory messages, which indicate system faults, also appear on the upper CRT. This combination of primary engine indications and crew alerting messages is called the EICAS Primary Display.

EICAS records RPM and EGT exceedance conditions in an auto event memory. The maximum exceedance value is displayed in smaller white numbers below the actual value counter.


Secondary Engine Indications
Eicas Lower

EICAS Display Switches N2, Fuel Flow, Oil Pressure, Oil Temperature, Oil Quantity and Engine Vibration are secondary engine indications [and] are displayed on the lower EICAS display. The secondary indications can be displayed by pushing the Engine Display Switch (the ENGINE switch on the EICAS control panel). The secondary engine indications are automatically displayed when:

When the Status Display Switch is pushed, the lower EICAS display changes to show the Status Page for other pre-flight checks, typically including hydraulic contents, APU EGT and Oxygen contents.

Normal Display Format

Primary engine indications and the N2 and Fuel Flow indications are digital readouts and round dial/moving pointer indications. The digital readouts display numerical values while the moving pointers indicate relative value.

Oil Pressure, Oil Temperature, Oil Quantity and Engine Vibration indications are both digital readouts and vertical indication/moving pointers. All digital readouts are enclosed by boxes. The dial and vertical indications display the normal operating range, caution range and operating limits (as applicable).

Normal operating range is displayed on a dial or vertical indication in white.

Non-Normal Indications

The Oil Temperature and Oil Pressure vertical indications have caution ranges displayed by amber bands. If oil temperature or oil pressure reaches the caution range, the digital readout, digital readout box, and pointer all change colour to amber.

N1, EGT, N2, Oil Pressure, and Oil Temperature indications have operating limits indicated by red lines. If one of these indications reaches the red line, the digital readout, box, and pointer change colour to red for that indication.

The EGT indication has a maximum continuous limit represented by an amber band. If EGT reaches the maximum continuous limit, the digital indication, box, pointer, and dial all change colour to amber. EGT indications are inhibited from changing to amber during takeoff or go-around for five minutes.

The red line limits for these parameters are not inhibited. The EGT indication has a maximum takeoff limit displayed by a red line. If EGT reaches the maximum takeoff limit, the digital indication, box, pointer and dial, all change colour to red.

The maximum N1 limit is indicated by an amber line at the top of the N1 dial. The N1 indication does not change colour when maximum N1 is reached. The reference/target N1 indication displays the FMS reference or target N1. The commanded N1 indication displays the EEC calculated N1 commanded by thrust lever position.

Automatic Call-up

EICAS Incorporates an automatic call-up feature that displays information automatically when necessary.

If the EICAS Secondary Display is not in view and N2 RPM reaches the amber Band or Red line limit, N2 indications are automatically displayed. Should oil Pressure or Temperature reach the Amber Band or Red line limit, or should the oil quantity decrease into the low quantity band, all oil parameters for both engines are automatically displayed. If the engine vibration reaches the amber band, both engine vibration displays appear on EICAS. If the status page is displayed when a secondary engine exceedance occurs, the status page is automatically replaced by the engine exceedance parameters. If status is selected after a secondary exceedance has occurred, the status page is displayed and the engine exceedance appears on the upper CRT in a partial, compacted mode.

EICAS records RPM and EGT exceedance conditions in an auto event memory. The maximum exceedance value is displayed in smaller white numbers below the actual value counter.

Special Condition Annunciations

During start, a red Maximum Start EGT radial appears at 750°C on the respective EGT display. This EGT limit remains in view until the engine start is completed.

During takeoff or go-around, the EGT, N1 and N2 pointers and digital readouts remain white for 5 minutes after the amber range is reached. If engine failure occurs during this 5-minute period, then the total amber band inhibit time period is extended to 10 minutes. The Red Line Limits for these parameters are not inhibited.

The N1 parameter displays a green TAI annunciation when the engine anti-ice is on.

Compact Display Format

Compact Display Format In compact format, primary and secondary engine indications are combined on the same display. The N1 and EGT displays are the same as the normal displays. All other indications change to digital readouts only. If an amber or red line parameter for a digital indication is exceeded, the digital indication changes colour to amber or red (as does the box that appears around an EGT indication).

Primary and secondary engine indications are displayed on EICAS in compact format whenever a CRT fails.

Note: 'Compact Display Mode' is also referred to as 'Full Engine Mode' in the Warning Systems section.


Engine Secondary Data Cue

EICAS Upper Secondary Cues. A series of blue 'v's are visible on the lower left corner of the upper EICAS CRT any time engine data is displayed on the lower EICAS CRT. If for some reason the engine data is not visible, the Status Display Switch may be used to allow the engine data to come up partially compacted on the upper EICAS CRT display.

Standby Engine Indicating
Standby Engine Indicator (SEI)
With the Standby Engine Indicator selector in AUTO:

  • display is blank with AC power on the airplane and EICAS operative.
  • standby engine indications in view when:
    • AC power is lost.
    • Either CRT failed and Status selected on the ground.
    • EICAS (both computers) failed.


N1 RPM

N1 RPM is the primary thrust parameter used for monitoring and setting power.

Annunciations associated with N1 are:

Engine Pressure Ratio

Fan Inlet Temperature. Note: although N1 is the primary thrust parameter and EPR is not displayed, it is still measured and is the pressure ratio between the LP compressor cold exhaust stream and engine air intake pressure.

However, the recessed probes visible in the Fan Inlet at the 10:00 and 2:00 o'clock positions, are not EPR probes, but are Fan Inlet Temperature sensors (one per EEC channel).

Controls Next